1.
Diabetes Technol Ther ; 25(11): 800-807, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37672562

RESUMO

Objective: To describe management strategies that contributed to optimal outcomes in pediatric recipients of a total pancreatectomy with islet autotransplantation (TPIAT). Research Design and Methods: We provide a comprehensive report of the approach to endocrine management of the pediatric TPIAT recipient from initial evaluation through the first 4 years postsurgery. We performed a retrospective review of the endocrine outcomes of TPIAT recipients to describe the impact of this approach on post-TPIAT glycemic management. Results: Outcome data from 86 TPIAT recipients were reviewed. At 12 months post-TPIAT (n = 82), the median HbA1C was 6.0% (25-75th percentile 5.6-6.7), at 18 months (n = 56) HbA1C was 6.4% (5.6-7.5), at 2 years (n = 46) HbA1C was 6.4% (5.6-7.4), at 3 years (n = 31) HbA1C was 6.5% (5.5-8.1), and at 4 years (n = 16) HbA1C was 7.2% (6.2-8.3). Conclusions: Pediatric patients at our institution have favorable endocrine outcomes as evidenced by median HbA1C under the goal of 6.5% through the initial 3 years by following our modified management protocols.


Assuntos
Transplante das Ilhotas Pancreáticas , Pancreatite Crônica , Humanos , Criança , Transplante Autólogo/métodos , Hemoglobinas Glicadas , Pancreatectomia , Pancreatite Crônica/cirurgia , Resultado do Tratamento
2.
J Clin Med ; 12(9)2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37176759

RESUMO

We previously published that insulin pump initiation immediately after IV insulin therapy was associated with improved post-surgical glycemic outcomes compared to multiple daily injections (MDI) in pediatric patients following a total pancreatectomy with islet autotransplantation (TPIAT). We investigated metabolic outcomes of this population at one-year post-TPIAT to assess if the improved outcomes in the early pump group were sustained over time. We retrospectively reviewed 40 patients post-TPIAT previously studied at 10-days post-surgery (15 used MDI and 25 used pump therapy immediately post-ICU, and all were discharged on pump therapy). Data analyzed included: demographics, islet equivalents per kilogram (IEQ/kg) transplanted, exogenous insulin use, and baseline vs. one-year (via mixed meal testing) HbA1c, fasting glucose, insulinogenic index, and the area under the curve (AUC) for insulin and c-peptide. More patients were off insulin at one year in the early pump group compared to the MDI group (45% vs. 13%, p = 0.07). Of all patients off insulin, 100% of the early pump users weaned off by six months post-TPIAT compared to 30% of the MDI users. Two known variables associated with favorable insulin outcomes, lower age and higher IEQ/kg, were not significantly different between groups. Fasting glucose was lower in the early pump group compared to the MDI group (median 97 vs. 122 mg/dL, p = 0.003), while AUC c-peptide was greater in early pump users at one-year post-TPIAT but did not reach significance (median 57.0 vs. 50.3 ng/mL × minutes, p = 0.14). Other metabolic outcomes did not differ between groups. Despite lower median age and higher IEQ/kg in the MDI group, the early pump group had a lower fasting glucose. Younger TPIAT age (p = 0.02) and early pump users (p = 0.04) were significantly associated with insulin independence at one year. This study was limited by sample size. Early pump use may have long-term benefits in post-TPIAT endogenous insulin secretion.

3.
Pancreatology ; 22(8): 1175-1180, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36198489

RESUMO

BACKGROUND: Hepatic steatosis has been described as a common finding in adults following total pancreatectomy with islet autotransplantation (TPIAT) but it is unknown if this occurs in children and adolescents. OBJECTIVES: To define the frequency of post-TPIAT hepatic steatosis in a sample of children and adolescents and to identify clinical predictors of incident steatosis post-TPIAT. METHODS: In this prospective study, consecutive participants at least 1-month post-TPIAT underwent a liver MRI with proton density fat fraction (PDFF) and blood draw at our pediatric academic medical center between April 2021 and January 2022. Comparison clinical pre-TPIAT liver MRI or ultrasound and insulin use and graft function data were extracted from the medical record. T-tests were used for the comparison of means across continuous variables between participants with and without post-TPIAT steatosis. RESULTS: A total of 20 participants (mean: 13 ± 4 years; 12 female) were evaluated. Mean liver PDFF at research MRI was 7.4 ± 6.2% (range: 2-25%). Seven participants (35%) had categorical hepatic steatosis (PDFF>5%) post-TPIAT, five of whom had pre-TPIAT steatosis, reflecting a 13% (2/15; 95% CI: 2-40%) incidence of post-TPIAT steatosis. Participant characteristics were not significantly different between subgroups with and without post-TPIAT steatosis. Mean PDFF at research MRI was not different between graft function subgroups (7.5% optimal/good vs. 7.3% marginal/failure; p = .96). CONCLUSION: Our study shows a moderate prevalence but low incidence of hepatic steatosis in a small sample of children and adolescents post-TPIAT. This study raises questions about a causal relationship between TPIAT and hepatic steatosis.


Assuntos
Fígado Gorduroso , Transplante das Ilhotas Pancreáticas , Adulto , Humanos , Criança , Adolescente , Feminino , Pancreatectomia/efeitos adversos , Transplante Autólogo , Estudos Prospectivos , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/epidemiologia , Fígado Gorduroso/etiologia , Imageamento por Ressonância Magnética , Transplante das Ilhotas Pancreáticas/efeitos adversos
4.
J Clin Med ; 10(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064129

RESUMO

Total pancreatectomy with islet autotransplantation (TPIAT) is a surgical procedure for patients with chronic pancreatitis and poor quality of life. Euglycemia is critical for islet cell survival and engraftment. We reviewed clinical care practice and hypothesized that early in-hospital transition from intravenous insulin to insulin pump therapy, managed by an endocrine unit trained on post-surgical care, would improve glucose control and impact the length of hospital stay. We completed a retrospective analysis of 40 pediatric patients who underwent TPIAT. Comparative hospitalized postoperative groups included those who received insulin intravenously, followed by multiple daily injections, subsequently managed by pump therapy (n = 14), versus those who received insulin intravenously followed by early pump therapy provided on the endocrine unit trained to manage post-surgical patients (n = 26). The outcomes analyzed included percentage of blood glucoses in target (4.44-6.66 mmol/L (80-120 mg/dL)), hypoglycemia (<3.33 mmol/L (<60 mg/dL)) and hyperglycemia (>7.77 mmol/L (>140 mg/dL)), blood glucose variability, and length of hospital unit stay post-ICU. Hospitalized patients with early transition to pump therapy on a specialized endocrine unit had a higher proportion of glucose values in the target range (61% vs. 51%, p = 0.0003), a lower proportion of hyperglycemia (15% vs. 19%, p = 0.04), and a lower proportion of hypoglycemia, though not statistically significant (3.4% vs. 4.4%, p = 0.33). Early pump users also had lower variability in glucose values over 10 days post-intravenous insulin (p = 0.001), and the post-transition median length of stay was shorter by 5 days (median: 11.5 vs. 16.5 days, p = 0.005). Early in-hospital pump therapy managed by the specialized endocrine unit improved glucose outcomes and reduced the duration of in-unit stay.

5.
J Clin Med ; 10(9)2021 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-33925523

RESUMO

Hyperglycemia is detrimental to postoperative islet cell survival in patients undergoing total pancreatectomy with islet autotransplantation (TPIAT). This makes continuous glucose monitoring (CGM) a useful management tool. We evaluated the accuracy of the Dexcom G6 CGM in pediatric intensive care unit patients following TPIAT. Twenty-five patients who underwent TPIAT had Dexcom G6 glucose values compared to paired serum glucose values. All paired glucose samples were obtained within 5 minutes of each other during the first seven days post TPIAT. Data were evaluated using mean absolute difference (MAD), mean absolute relative difference (MARD), %20/20, %15/15 accuracy, and Clarke Error Grid analysis. Exclusions included analysis during the CGM "warm-up" period and hydroxyurea administration (known drug interference). A total of 183 time-matched samples were reviewed during postoperative days 2-7. MAD was 14.7 mg/dL and MARD was 13.4%, with values of 15.2%, 14.0%, 12.1%, 11.4%, 13.2% and 14.1% at days 2, 3, 4, 5, 6 and 7, respectively. Dexcom G6 had a %20/20 accuracy of 78%, and a %15/15 accuracy of 64%. Clarke Error Grid analysis showed that 77% of time-matched values were clinically accurate, and 100% were clinically acceptable. The Dexcom G6 CGM may be an accurate tool producing clinically acceptable values to make reliable clinical decisions in the immediate post-TPIAT period.

6.
Diabetes Technol Ther ; 23(6): 443-451, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33314990

RESUMO

Objective: To assess the degree, duration, mean absolute relative difference (MARD), and error analysis of discrepant values per continuous glucose monitoring (CGM) systems after hydroxyurea (HU) administration. Research Design and Methods: Inpatient glucometer and CGM data from 16 total pancreatectomy/islet autotransplantation patients using Dexcom Professional G4 and 12 patients using Dexcom G6 were analyzed after daily dosing with HU. Timing of HU dosing and median of 9.5 days of sensor and glucometer values were assessed per patient. Results: A large positive elevation of sensor readings was identified after HU dosing. The greatest discrepancy between glucometer and sensor readings occurred 0.5-2 h after HU administration [G4 (mean 3.0 mmol/L, median 2.4 mmol/L, MARD 55%), G6 (mean 4.2 mmol/L, median 4.6 mmol/L, MARD 91%)]. The discrepancy was <1.1 mmol/L, mean (-0.5 mmol/L) and median (-0.5 mmol/L), MARD 14% (G4) and <1.1 mmol/L, mean (0.3 mmol/L) and median (0.3 mmol/L), MARD 17% (G6), by 6 h after administration. Error analysis with the G6 system found 94% of pairs in clinically acceptable range by 6-9 h after HU administration. Aspirin, also given once daily, did not result in glucose value discrepancy with the G6 system but variability was observed with the G4 system. Conclusions: There was marked elevation of sensor glucose readings compared with glucometer values [up to 13.9 mmol/L (G4), 13 mmol/L (G6)] from 0.5 to 6 h after HU administration. It is important to counsel a patient using a Dexcom CGM system and HU therapy on this finding and to advise reliance on glucometer testing for accurate glucose assessment up to 6-9 h after HU administration.


Assuntos
Diabetes Mellitus Tipo 1 , Hidroxiureia , Glicemia , Automonitorização da Glicemia , Glucose , Humanos
7.
J Endocr Soc ; 4(12): bvaa154, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33195956

RESUMO

Treatment-induced neuropathy of diabetes (TIND) is a small fiber neuropathy precipitated by rapid correction of hyperglycemia. Literature on TIND in pediatric diabetes is scarce. We present 7 cases of TIND in children and young adults, increasing awareness of this condition in pediatric diabetes and broadening the scope of published knowledge.